Rev. bras. oftalmol ; 80(1): 71-76, jan.-fev. 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1251315

ABSTRACT

RESUMO O artigo tem como objetivo descrever de forma prospectiva diferentes casos de ectasias altamente assimétricas (very asymmetric ectasia, VAE) para diferenciar formas subclínicas ou "frustas" do ceratocone (forme fruste keratoconus - FFKC) de casos de doença ectásica unilateral. O Caso 1 é um paciente de 39 anos, que admitiu ter coçado intensamente apenas o olho direito (OD) na juventude, se apresentando com ectasia unilateral tratada com sucesso por meio de implante de anel intraestromal em OD. O olho esquerdo (OE) apresentou-se normal ao exame completo por meio de propedêutica multimodal e acuidade visual não corrigida (AVsc) de 20/20, estável por mais de 5 anos, com TBI (tomography and biomechanical index) de 0.02. No Caso 2 é um paciente de 15 anos com ectasia clínica em OD, e OE com topografia normal, mas alterações tomográficas e biomecânicas, incluindo o TBI 0,56, caracterizarando a doença subclínica (FFKC). O Caso 3 é a mãe do paciente do Caso 2, de 46 anos, que se apresentou com presbiopia, sem qualquer histórico oftalmológico relevante. A AVsc foi de 20/20 em cada olho, topografia de Placido com leve encurvamento inferior, mas sem sinais definitivos de ectasia. A avaliação biomecânica e tomográfica revelou sinais de ceratocone em ambos os olhos, com TBI de 1,0 e 0,99. Esses três casos estão de acordo com a definição do consenso global e a hipótese de dois acertos (two-hit hypothesis), que ceratocone é uma doença bilateral, mas ectasia pode ocorrer por causa estritamente mecânica unilateralmente (ou em qualquer olho). A relevância da propedêutica multimodal é destacada, destacando-se a integração do estudo biomecânico e tomográfico com imagens de Scheimpflug.


ABSTRACT The article aims to prospectively describe different cases of highly asymmetric ectasia (very asymmetric ectasia, VAE) to differentiate subclinical or "frustrated" forms of keratoconus (forme fruste keratoconus - FFKC) from cases of unilateral ectatic disease. Case 1 is a 39-year-old patient with unilateral ectasia treated with an intrastromal ring implant. The contralateral eye was normal due to multimodal propaedeutics, stable for more than 3 years, with a TBI of 0.02. The patient admitted to having intensely scratched only his right eye in his youth. In Case 2, a 15-year-old patient with clinical ectasia in the right eye, had a left eye with normal topography and tomographic and biomechanical changes characterizing FFKC. Case 3 is the mother of the case 2 patient, aged 46, who presented with presbyopia, without any relevant ophthalmological history. Uncorrected visual acuity of 20/20 in each eye, Placido topography with slight lower curving, but without definitive signs of ectasia. The biomechanical and tomographic evaluation revealed signs of keratoconus in both eyes. These three cases are in accordance with the definition of the global consensus: keratoconus is a bilateral disease, but ectasia can occur because of strictly mechanical unilateral (in any eye). The relevance of multimodal refractive imaging is highlighted, with a focus on integrating biomechanical and tomographic assessments with Scheimpflug images.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Biomechanical Phenomena , Tomography/methods , Corneal Topography/methods , Dilatation, Pathologic , Keratoconus/diagnosis , Epidemiology, Descriptive
2.
Rev. bras. oftalmol ; 79(6): 420-425, nov.-dez. 2020. tab, graf
Article in Portuguese | LILACS | ID: biblio-1156163

ABSTRACT

Resumo Objetivo: Realizar uma revisão sobre o diagnóstico do ceratocone, com enfoque nos métodos propedêuticos disponíveis. Métodos: Foi realizada uma pesquisa no banco de dados PubMed com as palavras chave: Keratoconus, diagnosis, topography e tomography. Por se tratar de uma revisão, não houve restrição de período para a publicação dos artigos selecionados. Foram também utilizados o manual Prefered Practice Pattern(PPP) da academia americana de oftalmologia, assim como o site "eyewiki.aao.org". Resultados: Dos 641 artigos encontrados no PubMed, assim como os usados como referência para o PPP, 36 foram selecionados por serem considerados mais relevantes para o tema proposto. O site "eyewiki.aao.org" foi utilizado como referência para as figuras. Conclusão: O diagnóstico do ceratocone evoluiu consideravelmente desde quando foi primeiramente descrito. É desejável que seja feito em suas fases precoces devido ao alto potencial de morbidade desta doença. Uma possível integração entre os múltiplos índices diagnósticos, investigação genética, biologia molecular e inteligência artificial é almejado para uma maior acurácia diagnóstica.


Abstract Objective: To Perform a review on the diagnosis of keratoconus, focusing on the available propaedeutic methods. Methods: A search was performed in the PubMed database using the key words: Keratoconus, diagnosis, topography and tomography. As it is a review, there was no restriction regarding the publication period of the selected articles. Furthermore, both the preferred practice pattern(PPP) manual of the American Academy of Ophthalmology, as well as the website "eyewiki.aao.org" were used as reference. The project was submitted to the research ethics committee of the Federal University of São Paulo / UNIFESP / SP 2018 (# 2,568,770). Results: Out of the 641 papers found in PubMed, in adition to those used as a reference for PPP, 36 were selected while considered more relevant to the adopted theme. The website "eyewiki.aao.org" was used as a reference for the images. Conclusion: The diagnosis of keratoconus has evolved considerably since it was first described. It is desirable to diagnose it on the early stages due to its high potential of morbility. A possibility of an integration between the various diagnostic indices, genetic research, molecular biology and artificial intelligence is recommended for greater diagnostic accuracy.


Subject(s)
Humans , Male , Adolescent , Middle Aged , Tomography/methods , Corneal Topography/methods , Keratoconus/diagnosis , Biomechanical Phenomena , Dilatation, Pathologic
3.
Rev. bras. oftalmol ; 78(6): 375-379, nov.-dez. 2019. tab
Article in English | LILACS | ID: biblio-1057921

ABSTRACT

Abstract Purpose: To investigate the patients' perspectives regarding the introduction of the electronic medical record into use in an ophthalmologic hospital and its impact on the doctor/patient relationship. Methods: The cross-sectional study analyzed the impact of the electronic medical record on the doctor-patient relationship based on the patients' opinions after electronic medical record implementation compared with use of traditional paper records. The same doctor attended all patients and completed questionnaires during patient interviews that analyzed empathy, punctuality, efficiency, information clarity, doctor cordiality, respect, trustworthiness, patient benefits from the technology, confidentiality, and humanized care. The inclusion criteria included age of 18 years or older, adequate cognition, previous treatment in the same institution by the same doctor using paper medical records and later the electronic medical record, and free and informed written patient consent. The exclusion criteria included age below 18 years, inadequate time to answer the questionnaire, first patient visit, doubtful interview responses, and first visit before 6 months after electronic medical record implementation. The data were analyzed descriptively by relative and absolute frequencies. A previous pilot study of 20 patients yielded 95% confidence intervals for the percentages of agreement for the electronic medical record questionnaire responses obtained and found that 160 patients was adequate for performing the study. Results: The patients reported that the electronic medical record had a positive impact on the doctor-patient relationship in all areas considered. Over 94% of patients responded affirmatively when questioned about their confidence in the confidentiality of their data, 38.3% noted changes in the doctor's concern for service and 68% agreed that clarity of the information provided by the doctor was greater with the electronic medical record. Conclusion: Based on the patients' perceptions, the EMR positively affected the doctor-patient relationship after the implementation of the technology in a private ophthalmologic hospital.


Resumo Objetivo: Investigar as perspectivas dos pacientes em relação à introdução do prontuário eletrônico em uso em um hospital oftalmológico e seu impacto na relação médico / paciente. Métodos: O estudo transversal analisou o impacto do prontuário eletrônico na relação médico-paciente com base na opinião dos pacientes após a implementação do prontuário eletrônico em comparação com o uso de registros tradicionais em papel. O mesmo médico atendeu a todos os pacientes e completou questionários com pacientes que analisaram empatia, pontualidade, eficiência, clareza da informação, cordialidade do médico, respeito, confiabilidade, benefícios para o paciente da tecnologia, confidencialidade e cuidado humanizado. Os critérios de inclusão incluíam idade de 18 anos ou mais, cognição adequada, tratamento prévio na mesma instituição pelo mesmo médico, usando registros médicos em papel e, posteriormente, o prontuário eletrônico e consentimento livre e esclarecido por escrito do paciente. Os critérios de exclusão incluíram, idade abaixo de 18 anos, tempo inadequado para responder ao questionário, primeira consulta do paciente, respostas duvidosas à entrevista e primeira visita antes de 6 meses após a implementação do prontuário eletrônico. Os dados foram analisados descritivamente por frequências relativas e absolutas. Um estudo piloto prévio de 20 pacientes forneceu intervalos de confiança de 95% para as porcentagens de concordância para as respostas do questionário de prontuário eletrônico obtido e constatou que 160 pacientes eram adequados para realizar o estudo. Resultados: Os pacientes relataram que o prontuário eletrônico teve impacto positivo na relação médico-paciente em todas as áreas consideradas. Mais de 94% dos pacientes responderam afirmativamente quando questionados sobre sua confiança na confidencialidade de seus dados, 38,3% observaram alterações na preocupação do médico com o serviço e 68% concordaram que a clareza das informações fornecidas pelo médico era maior com o prontuário eletrônico. Conclusão: As vantagens do prontuário eletrônico foram o rápido acesso à informação, clareza dos dados, recuperação rápida e organizada da informação e agilidade nos serviços.


Subject(s)
Humans , Physician-Patient Relations/ethics , Electronic Health Records/ethics , Medical Records , Cross-Sectional Studies , Surveys and Questionnaires , Medical Records Systems, Computerized/ethics , Communication , Confidentiality , Trust
4.
Rev. bras. oftalmol ; 78(5): 342-344, Sept.-Oct. 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1042388

ABSTRACT

Resumo Objetivo: Revisar criticamente a literatura sobre o implante intraocular da Lente Macular Scharioth (SML) em pacientes com estágios avançados de Degeneração Macular Relacionada à Idade (DMRI). Métodos: A pesquisa bibliográfica foi feita nas bases de dados do Pubmed e Google Acadêmico, com os termo dry AMD, devices e Scharioth Macula Lens. Utilizamos os artigos prospectivos, retrospectivos ou relatos de casos publicados em inglês ou português nos últimos cinco anos, com esses termos. Resultados: Foram encontrados um total de 19 artigos, todos em inglês. Sendo que destes, 5 relacionavam-se a complicações da cirurgia de catarata e outro à degeneração macular exsudativa e foram excluidos. Portanto, foram utilizadas 13 referências para esta revisão. Conclusão: A Scharioth Macula Lens foi desenvolvida como lente intraocular suplementar para olhos pseudofácicos com DMRI, mas vem sendo usada também em pacientes com outra maculopatias. Os resultados iniciais relatados são animadores.


Abstract Objective: In this review we critically evaluated the publications on the intraocular implant of the Scharioth Macular Lens (SML) in patients with advanced stages of Age-Related Macular Degeneration (AMD). Methods: The literature search was done in Pubmed and Google Scholar database, with the term dry AMD, devices and Scharioth Macula Lens. We use prospective, retrospective articles or case reports published in English or Portuguese in the last five years under these terms. Results: A total of 19 articles were found, all in English. Of these, 5 were related to complications of cataract surgery and another to Exudative Macular Degeneration. Therefore, 13 references were used for this review. Conclusion: Scharioth Macula Lens was developed for pseudophakic eyes with AMD and has also been used in patients with other maculopathies. The initial results reported are encouraging.


Subject(s)
Visual Acuity , Lens Implantation, Intraocular , Lenses, Intraocular , Macular Degeneration